page 1 of 5 universal power supplies txh 600 series, 600 watt features universal input: 90C264 vac or 120C370 vdc active power factor correction (>0.95) high effciency up to 93% current share function for up to 3 units in parallel adjustable output voltage emi/emc compliance with en 61000-6-3 and en 61000-6-1 remote control input rear side iec-c13 line socket, including mains switch and fuse dc-ok signal and 5 vdc auxiliary output protection against over-voltage, over- temperature, overload and short circuit 3-year product warranty ul 60 95 0- 1 cb scheme order code output power max. output voltage nom. output current max. effciency typ. txh 120/240/360/480 120 C 480 watt see: www.tracopower.com/products/txh.pdf txh 600-112 540 watt 12 vdc 45 a 90 % txh 600-124 600 watt 24 vdc 25 a 92 % txh 600-148 600 watt 48 vdc 12.5 a 92 % txh 600-154 600 watt 54 vdc 11.1 a 93 % models the txh 600 series models are very compact 600 watt universal power supplies. rear side iec-c13 line socket including mains switch and fuse and the output screw terminal make the connection of these power supplies very easy. sense line, auxil - iary output, remote control, adjustable output voltage, and current share line for up to 3 units in parallel make the units all-purpose applicable. they come with an active power factor correction. the emc characteristic is dedi - cated for applications in industry, it and domestics. the protection against over- voltage, over-temperature, overload and short circuit and a high effciency of up to 93% guaranties a reliable operation. http://www.tracopower.com
page 2 of 5 universal power supplies txh 600 series 600 watt input specifications input voltage C nominal 100 C 240 vac C ac range (universal input) 90 C 264 vac C dc range 120 C 370 vdc C output power derating at operation below 110 vac 1%/v (110 - vin) input frequency 47 C 63 hz earth leakage current (240 vac / 63 hz) 3.5 ma max. harmonic limits en 61000-3-2, class a & d C power factor >0.99 at 115 vac, >0.95 at 230 vac input current at full load C at 115 vac / 230 vac rated 8.0 a / 3.5 a typical: 6.0 a / 2.9 a circuit breaker (slow blow fuse) 16 a internal output specifications voltage set accuracy 2 % max. output voltage adjustment range 5 % with internal potentiometer regulation C input variation 1 % max. C load variation (0C100%) 1 % max. minimum load 1% ripple and noise (20 mhz bandwidth) <1% vout [mvp-p] hold-up time 12 ms min. current limitation auto recovery short circuit protection no auto recovery (power disconnect required) overvoltage protection by zener diode 120 % of vout typ. auto recovery overtemperature protection auto recovery capacitive load, [f] max. 12 vdc models: 60000 f max. 24 vdc models: 50000 f max. 48 vdc models: 20000 f max. 54 vdc models: 10000 f max. general specifications temperature ranges C operating C25c to +65c C storage (non operating) C25c to +85c derating 4 %/k above +50c temperature coefficient 0.03 %/k humidity (non condensing) 95 % rel max. switching frequency (pulse width modulation pwm) 110 khz typ. 10% isolation voltage (60 sec.) C input/output 3000 vac C input/case 150 0 vac C output/case 500 vac reliability /calculated mtbf (mil-hdbk-217f, at +25c, ground benign) >100000 h all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. http://www.tracopower.com
page 3 of 5 block diagram general specifications electromagnetic compatibility (emc), emissions en 61000-3-2:2006+a1:2009+a2:2009 en 61000-3-3:2008 en 55022, class b electromagnetic compatibility (emc), immunity en 55024 C electrostatic discharge esd en 61000-4-2 2 kv / 4 kv, criteria a C rf field susceptibility en 61000-4-3 3 v/m, criteria a C electrical fast transient / burst immunity input en 61000-4-4 1 kv, criteria a C surge immunity line C neutral en 61000-4-5, 1 kv, criteria a C surge immunity line C pe, neutral C pe en 61000-4-5 2 kv, criteria a C immunity to conducted rf disturbances en 61000-4-6 3 v, criteria a C power frequency magnetic field immunity en 61000-4-8 1 a/m, criteria a C mains voltage dips and interruptions en 61000-4-11 30 % 500 ms, criteria a 95 % 10 ms, criteria a 95 % 2500 ms, criteria b emc test report www.tracopower.com/products/TXH600-emc.pdf degree of protection class i safety standards ul 60950-1, iec 60950-1 2nd: am 1, en 60950-1:2006/a11:2009/a1:2010/a12:2011 safety approvals C ul online certification ul/cul 60950 -1 www.ul.com -> certifications -> file e188913 C cb certificate according to iec/en 60950-1 www.tracopower.com/products/TXH600-cb.pdf environment C vibration 3 axes, sine sweep, 10C500hz, 2g, 0.1 oct/min altitude during operation up to 2000 m (6560 ft) environmental compliance C reach www.tracopower.com/products/txh-reach.pdf C rohs rohs directive 2011/65/eu universal power supplies txh 600 series 600 watt http://www.tracopower.com
page 4 of 5 functions control connector c1 + sense c2 C sense c3 current share c4 gnd (internal connection to Cvout) c5 c6 remote control: open = on, short to gnd = off c7 dc-ok signal: 4-6 vdc = on, 0-1 vdc = off c8 +5 vdc aux. 10%, 0.6 a max. -v out +v out parallel operation: ? difference in vout among paralleled units should be less than +/-1% ? output power at parallel operation = rated power per unit x number of unit x 80% ? shorter wiring to each unit is recommended, as well as twisting +s and -s in pairs, as shown. universal power supplies txh 600 series 600 watt 8 6 4 2 7 5 3 1 8 6 4 2 7 5 3 1 8 6 4 2 7 5 3 1 8 6 4 2 7 5 3 1 -v out +v out load ps2 ps1 ps3 cs cs cs +s -s +s -s +s -s +s -s -v out +v out -v out +v out vout terminals are rated for 25 a max. at higher current connection has to be splitted. mating connector: housing: jst phdr-08vs crimp: jst sphd-002t-p0.5 connection cable with 500mm fying leads included! http://www.tracopower.com
outline dimensions weight: 1030 g dimensions in [mm] tolerance 05 mm max. mounting screw penetration: 2.5 mm page 5 of 5 sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com rev. january 17. 2014 connection 1 ac in iec-c13 line socket 2-4 + vout 5-7 C vout universal power supplies txh 600 series 600 watt
|